cDNA was made from the above RNA samples using the Qiagen Quantitect RT Kit. The samples were laid out in a PCR plate. 274.2ng of RNA was used in the rxn for each sample, based on the lowest concentration RNA sample (08:3-20) to equalize all the samples. The Genomic Wipeout step of the kit requires 2uL of Genomic Wipeout enzyme/buffer to be added to 12uL of an RNA sample, so the calculations were done and can be found here. A check mark on the calculation sheet indicates that the water and then the RNA was added to the appropriate wells. Those with two check marks were used for a “No RT” rxn and thus, have duplicate wells (see plate layout).
The plate was mixed, spot spun, uncubated at 42C for 2mins and immediately placed on ice.
The RT and No RT master mixes were set up on ice and then added to the respective wells (see sheet here).
UPDATE: cDNA plate was discarded 20120320 by SJW.